Infection control in endoscopy

Get an overview of the three main challenges associated with infection control and reprocessing. Also, learn how sterile single-use endoscopes free up time otherwise used on reprocessing, reduce the risks of patient cross-contamination and improve patient safety.

Leading authorities recommend the transition to single-use endoscopy

There is a growing concern that, even with the most stringent high-level disinfection procedures, it is not possible to guarantee that reusable endoscopes are clean. Ambu® single-use endoscopes remove the risk of patient cross-contamination by eliminating reprocessing altogether.

The 3 main challenges of infection control in endoscopy

Challenge #1
Complex, costly and ultimately ineffective cleaning processes

icon + text: challenge 1

Challenge #2
Endoscope design inherently
difficult to clean

icon + text: challenge 2

Challenge #3
The ongoing battle with “superbugs” (multi-drug resistant organisms)

icon + text: challenge 3

Challenge #1

Complex, costly, and ultimately ineffective cleaning processes

Multiple studies have shown that regardless of the amount of resources spent and which guidelines were followed, no cleaning process effectively removes bacteria1-4. This has been true whether the reprocessing was performed using high-level disinfection (HLD), double HLD or HLD and sterilization combined5-6.

The steps below represent a condensed version of the basic recommended reprocessing actions. In reality, there can be more than 100 steps7.

Reprocessing steps:

PRE-CLEANING
CRUCIAL FOR AVOIDING BIOFILM

Important
Must be performed after procedure carefully following IFU.

LEAK TESTING
DETECT INTERNAL/EXTERNAL DAMAGE

Important
Damage can lead to inadequate disinfection & further deterioration.

MANUAL CLEANING
MOST CRITICAL STEP FOR DISINFECTION 

Important
Meticulous cleaning is a prerequisite to HLD and sterilisation.

VISUAL INSPECTION
ADDITIONAL SAFETY ASSURANCE

Important
The complex design of flexible endoscopes makes it difficult to detect problems.

DISINFECTION OR STERILISATION
CRITICAL TO ADHERE TO INSTRUCTIONS

Important
The FDA recommends double HLD, or sterilisation when feasible.

STORAGE
UNDER CONDITIONS THAT PROTECT FROM MOISTURE

Important
Incorrect storage can result in bacteria growth.

DOCUMENTATION
ESSENTIAL FOR QUALITY ASSURANCE  & TRACEABILITY

Important
Documentation of above steps needed each time an endoscope is reprocessed.

REPEAT PER PROCEDURE
AN ONGOING ENTERPRISE

Important
The steps shown here comprise only the basic recommended actions. Individual guidelines should be developed per institution by a multidisciplinary team.

If the margin of safety for endoscope reprocessing is so small that perfect compliance with >100 pages of the manufacturer’s instructions for use is required, then the endoscope design is too complex, the microbial load is too high, and the process is too unforgiving to be practical in the real world.7

William A. Rutala, PhD, MPHX

Challenge #2

Endoscope design inherently difficult to clean

Long, narrow channels, difficult-to-reach areas1, 8-9 and deterioration4-5, 10-11 and grooves formed due to routine use and cleaning make endoscopes susceptible to moisture and bacterial contamination.

Bacteria can reside in the remote switches, valves of the control handle, the recesses of the distal tip, the biopsy port and the working channel of all endoscopes. In GI endoscopes, bacteria can also hide in the remote switches, valves and the wheels of the control handle, and the complex design of the duodenoscope elevator is particularly difficult to clean.

In fact, the ECRI – a non-profit US patient safety organization –  has included the potential for cross-contamination and inadequate cleaning of endoscopes on their annual ECRI lists of “Top 10 Health Technology Hazards” multiple times.

Places bugs like to hide

  1. Bending lever
  2. Suction button
  3. Endoscope buttons
  4. Remote switches, valves and wheels
  5. Biopsy port
  6. Distal tip
  7. Distal tip with elevator
  8. Working channel

Challenge #3

The rise of the superbugs

The rise in recent years of Multi-Drug Resistant Organisms (MDROs), sometimes referred to as superbugs, has made it even more challenging to clean endoscopes.12-13 For example, more than 15 reported outbreaks related to MDROs have occurred since 200014.

Ambu single-use endoscopes are sterile straight from the pack

With Ambu single-use endoscopes, you:

  • check Can assure your patients that you will be performing the procedure with a single-use sterile endoscope opened straight from a sealed pack just for them.
  • check Eliminate the risk of patient cross-contamination.
  • check Remove the risk of patients developing allergies due to repeated exposure to disinfectant residuals after reprocessing.

The fact that all Ambu single-use endoscopes are phthalate-free, one of our many environmental initiatives, also contributes to patient safety.

Learn more about single-use benefits

Discover how Ambu’s sterile single-use endoscopes provide consistently high quality and performance, help streamline workflow and give you greater cost-transparency across multiple clinical areas.

SINGLE-USE BENEFITS

Learn about Ambu single-use endoscopes for different clinical areas

Pulmonology
Explore

Ear, Nose & Throat
Explore

Gastroenterology
Explore

Urology
Explore

References

1. Rauwers AW, Voor in ‘t holt AF, Buijs JG, de Groot W, Erler NS, Bruno MJ, Vos MC, Nationwide risk analysis of duodenoscope and linear echoendoscope contamination, Gastrointestinal Endoscopy (2020).

2. Rex DK, Sieber M, Lehman GA, et al. A double-reprocessing high-level disinfection protocol does not eliminate positive cultures from the elevators of duodenoscopes. Endoscopy. 2018;50(6):588-596.

3. Naryzhny I, Silas D, Chi K. Impact of ethylene oxide gas sterilization of duodenoscopes after a carbapenem-resistant Enterobacteriaceae outbreak. Gastrointestinal Endoscopy (2016).

4. Seidelman JL, Akinboyo IC, Taylor B, Henshaw NG, Abdelgadir A, Gray GC, Smith BA, Lewis SS. Pseudo-outbreak of adenovirus in bronchoscopy suite. Infect Control Hosp Epidemiol. 2021 Aug;42(8):1016-1017.

5. Snyder GM, Wright SB, Smithey A, et al. Randomized Comparison of 3 High-Level Disinfection and Sterilization Procedures for Duodenoscopes. Gastroenterology. 2017;153(4):1018-1025.

6. Ofstead Cori L, Quick Mariah R, Eiland John E, et al., 2017: A glimpse at the true cost of reprocessing endoscopes: Results of a pilot project. www.iahcsmm.org. https://www.bostonscientific.com/content/dam/bostonscientific/uro-wh/portfolio-group/LithoVue/pdfs/Sterilization-Resource-Handout.pdf. Accessed May 28, 2023.

7. Kovaleva J. Infectious complications in gastrointestinal endoscopy and their prevention. Best Pract Res Clin Gastroenterol. 2016;30(5):689-704.

8. Rutala WA, Kanamori H, Sickbert-Bennett EE, Weber DJ. What’s new in reprocessing endoscopes: Are we going to ensure “the needs of the patient come first” by shifting from disinfection to sterilization? Am J Infect Control. 2019 Jun;47S:A62–6.

9. Mark J, Underberg K, Kramer R, Results of duodenoscope culture and quarantine after manufacturer-recommended cleaning process, Gastrointestinal Endoscopy (2020).

9. Gavalda L, Olmo Ana Rosa, Hernandez R, etal., Hospital Bronchoscopy Quality Improvement Group. Respiratory Medicine (2015) 109, 1079-1085.

10. Ofstead CL, Wetzler HP, Heymann OL, Johnson EA, Eiland JE, Shaw MJ. Longitudinal assessment of reprocessing effectiveness for colonoscopes and gastroscopes: Results of visual inspections, biochemical markers, and microbial cultures. Am J Infect Control. 2017;45(2):e26-e33.

11. Barakat MT, Girotra M, Huang RJ, Banerjee S. Scoping the scope: endoscopic evaluation of endoscope working channels with a new high-resolution inspection endoscope (with video). Gastrointest Endosc. 2018;88(4):601-611.e1.

12. Mehta AC, Muscarella LF. Bronchoscope-Related "Superbug" Infections. Chest. 2020 Feb;157(2):454-469

13. US. Food and Drug Administration. Flexible Bronchoscopes and Updated Recommendations for Reprocessing: FDA Safety Communication.  FDA Web site. https://www.fda.gov/medical-devices/safety-communications/flexible-bronchoscopes-and-updated-recommendations-reprocessing-fda-safety-communication. Published 2021. Accessed May 28, 2023.

14. Rubin ZA, Kim S, Thaker AM, Muthusamy VR. Safely reprocessing duodenoscopes: current evidence and future directions. Lancet Gastroenterol Hepatol. 2018;3(7):499-508. 

keyboard_arrow_up